Commercial RO Water System

Servicing

Sychem services, maintains, and tests reverse osmosis (RO) water treatment systems for endoscopy units, sterile services departments (SSDs) and laboratories. Our nationwide engineers carry out planned maintenance, sanitisation and water quality testing to HTM 01-06 and 01-01, with documentation that supports AE(D) audits and CQC and JAG inspections.

Planned Preventative Maintenance (PPM)

  • Six-monthly and annual service visits
  • Filters, membranes and UV lamps maintained
  • Scheduled around your endoscopy lists
Schedule your maintenance

Non-Contractual Support

  • Ad hoc servicing and repair support
  • Emergency call-out support available
  • Flexible support, contract-free
Request support

Validation & Compliance Testing

  • Annual TVC and endotoxin water testing
  • Most RO system manufacturers covered
  • Reports via SychemEYE portal
Book your validation

RO System Servicing Support

Water Testing Standards

We test RO water to the standards your site requires, including HTM 01-06 for endoscope washer-disinfector (EWD) final rinse water and HTM 01-01 for steriliser and washer-disinfector feed water. Testing to other standards is available on request

Sanitisation & Biofilm Control

RO membranes are chemically sanitised every six months to prevent biofouling. We thermally or chemically sanitise the storage tank and distribution loop every 12 months during the annual service.

Audit Ready Documentation

Every visit is documented to the same standard as our autoclave and washer-disinfector servicing, under our ISO 9001 quality management system. Reports support AE(D) audits, water safety group reviews and CQC and JAG inspections.

sychemwater_ro_system_filters_closeup
sychemwater_ro_system_front
sychemwater_ro_system_valves_closeup

SychemWATER RO Systems

Sychem Water is our own range of reverse osmosis systems, designed for endoscopy, sterile services and laboratory water treatment.

Explore Our RO Water Systems

What RO Systems do we service?

From endoscopy decontamination units and sterile services departments to laboratories and pharmaceutical facilities, our engineers service endoscopy water systems and RO and deionised (DI) water treatment systems from most manufacturers. Older and end-of-life units are surveyed first, and a condition report confirms the support available, as parts availability can limit servicing.

EWD final rinse water

Steriliser and washer-disinfector feed water

Laboratory and pharmaceutical water

RO System Servicing Explained

How often should an RO system be serviced?

Healthcare RO systems should be serviced at least twice a year, with a six-month and a 12-month service. Frequency depends on usage, incoming water quality, manufacturer recommendations and HTM requirements.

High-usage sites, such as central processing centres, may need quarterly visits, with pre-filter changes between the six- and 12-month services. We coordinate every visit with your team to limit downtime and disruption to endoscopy lists. Out-of-hours and weekend visits are available at an additional cost.

What does an RO system service include?

An RO system service covers pre-filter and carbon filter changes, softener checks, membrane performance checks, UV lamp replacement and 0.2 µm terminal filter changes. Engineers inspect the storage tank and ring main, service valves and replace O-rings where required. High-risk and high-dependency components are checked or replaced at agreed intervals.
Every visit includes performance validation, confirming water quality and output are within tolerance and the system is running correctly and efficiently. RO membrane cleaning and sanitisation are carried out as required.

Is the documentation suitable for AE(D) audits, water safety group reviews and CQC or JAG inspections?

Yes. Every visit is documented in a service report covering the work carried out, components replaced and system performance. Water test results are issued once the laboratory analysis is complete. Reports are stored on the SychemEYE portal, so records are available whenever an auditor or inspector asks for them.
Sychem Eye hero image

SychemEYE is a cloud-based portal improving the way you manage and monitor your equipment. Available to our servicing clients.

Request a servicing quote

Faster Access

Get instant access to your quarterly, biannual, and annual validation reports directly through the portal. Access essential information that supports compliance and audit-readiness.

Real-Time Management

Our SychemEYE portal provides seamless access to your service history, reports, and archived data.

Detailed Insights

View comprehensive equipment data for all your devices, allowing for quick, informed decisions and a proactive approach to maintenance and compliance.

FAQs

What is included in an RO system service?

An RO system service includes filter changes, softener and membrane checks, UV lamp replacement, terminal filter changes, valve servicing, tank and ring main inspection, and performance validation of water quality and output.

What is HTM 01-06?

HTM 01-06 is the Department of Health and Social Care’s Health Technical Memorandum for the management and decontamination of flexible endoscopes. It sets out requirements for endoscope washer-disinfectors (EWDs), including the microbiological quality of the final rinse water supplied by your RO system.

How do you maintain a reverse osmosis system?

Reverse osmosis system maintenance combines planned engineer visits with routine filter changes. At the six- and 12-month services, engineers replace carbon and terminal filters and UV lamps, check membrane performance and sanitise the system. Water quality testing confirms the system is performing within tolerance.

What water quality tests do you carry out?

Our water quality testing is tailored to your site’s requirements and includes:
– Total viable count (TVC)
– Endotoxin
– Mycobacteria, at commissioning
– Testing to HTM 01-06, HTM 01-01 or any other standard you require

Do you service all makes and models of RO systems?

Sychem service all makes and models of RO systems subject to a survey, a condition report and parts availability. End-of-life units can be serviced on a limited basis, with a view to replacement.

Keeping Your Facility Operational with Leading Servicing Solutions.

Get Specialist Advice Today
Get Specialist Advice Today

EMERGENCY SUPPORT

Out-of-Hours Technical Assistance

If you are experiencing an equipment emergency, don’t hesitate to call us immediately. Our out of hours number is manned 24/7.

Out of Hours

02380 013531

During Office Hours

02380 240729